Enter the Ip address from your LINKSYS in your web browser as an URL. You can find this on the LINKSYS IP_Phone under «Setup – Network – Current IP»

Cisco Linksys Firewall 1.jpg

Go on «Admin Login – advanced – Ext 1». In the chapter Proxy and Registration you need to enter the proxy «app.peoplefone.ch»

  • In the chapter Subscriber Information you need to enter the SIP username, the password and the SIP password from your peoplefone account.
  • Go to «Admin Login – advanced – SIP». In the chapter RTP Parameters you can change the RTP Packet Size to 0.020 instead of 0.030

Cisco Linksys Firewall 2.jpg

Further parameters can be examined if you have following problems:

Cisco Linksys Firewall 3.jpg
Outgoing calls don't work:
  • Go under «Admin Login – advanced – Ext 1». In the chapter SIP Settings change the SIP Remote-Party to «no».
Incoming calls don't work:
    • Go under «Admin Login – advanced – Ext 1». In the chapter NAT Settings change NAT Keep Alive Enable to «yes».
    • Go under «Admin Login – advanced – Ext 1». In the chapter Proxy and Registration change Register Expires to «300» (instead of 3600).
      Cisco Linksys Firewall 4.jpg
    • Go under «Admin Login – advanced – SIP». In the chapter NAT Support Parameters change STUN Enable to «no».Cisco Linksys Firewall 5.jpg